HYDROSHIELD WB

LOW ODOR, VOC COMPLIANT, CLEAR, NON-GLOSS PROTECTIVE COATING TO SEAL CONCRETE, MASONRY OR STUCCO.

 

PURPOSE:

HYDROSHIELD WB HAS BEEN PRIMARILY DESIGNED TO SEAL MASONRY WALLS, CONCRETE SLABS, DECKS, WALLS, AND ABUTMENTS FROM BOTH WATER AND CHLORIDE INTRUSION WHILE PROVIDING FOR WATER VAPOR TRANSMISSION (BREATH ABILITY)

 

HYDROSHIELD WB IS A SOLVENT FREE SILANE MODIFIED SILOXANE WHICH CHEMICALLY BONDS  TO THE SUBSTRATE.  THE HIGHLY HYDROPHOBIC CHEMICAL MOLECULES ARE EXTREMELY SMALL (17A) RESULTING IN PENETRATION DEPTHS OF 1/4 OF AN INCH.  THIS MATERIAL IS UV RESISTANT AND WILL NOT TURN YELLOW,  AND PROVIDES A BARRIER TO DESTRUCTIVE CARBONATION.

 

ADVANTAGES:

l    MARKEDLY REDUCES WATER AND CHLORIDE INTRUSION

l    BREATHABLE PROVIDING FOR WATER VAPOR TRANSMISSION

l CHEMICALLY RESISTANT TO ICE MELTING COMPOUNDS, FUELS, OILS AND ATMOSPHERIC CONTAMINANTS

l    INHIBITS EFFLORESCE

l INCREASES FREEZE-THAW RESISTANCE

l    PREVENTS STAINING AND DISCOLORATION DUE TO ELECTROSTATIC ATTRACTION OF DUST PARTICLES

l    CAN BE APPLIED TO DAMP SURFACES

l DEEP PENETRATION INTO SUBSTRATE

l    PROVIDES A BARRIER TO DESTRUCTIVE CARBONATION

l   TREATED SURFACE CAN BE PAINTED

 

SURFACE PREPARATION:

THE SUBSTRATE SHOULD BE STRUCTURALLY SOUND AND FREE OF GREASE, OIL, SEALERS, COATINGS OR OTHER SURFACE CONTAMINANTS.  HYDROSHIELD WB MAY BE APPLIED TO DAMP SURFACES PROVIDED NO SURFACE LIQUID EXISTS.

 

APPLICATION:

MIX MATERIAL TO REDISTRIBUTE ANY SETTLED INGREDIENTS.  APPLY DIRECTLY FROM THE CAN, WITH NO THINNING.  THE PRIME COAT OF THE HYDROSHIELD WB SHOULD BE ALLOWED TO DRY AT LEAST ½ HOUR BEFORE THE TOP COAT IS APPLIED.  APPLY MATERIAL ON WALLS IN A FLOOD COAT TO SATURATION STARTING AT THE TOP AND WORKING DOWN.  PROTECT WINDOWS FROM OVER SPRAY.  ON DECKS APPLY AT SUGGESTED COVERAGE RATES.

 

APPLICATION COVERAGE

PRIME COAT..........................................................................................100 SQ. FT PER GALLON

TOP COAT...............................................................................................200 SQ. FT PER GALLON

PRODUCT MAY BE EITHER SPRAYED OR ROLLER APPLIED.

 

 

 

APPEARANCE:

THE HYDROSHIELD WB SYSTEM WILL SLIGHTLY DARKEN THE SURFACE OF THE SUBSTRATE IT IS APPLIED TO.  HYDROSHIELD WB WILL NOT ALTER EITHER THE COLOR OR TEXTURE OF THE SURFACE.

 

ADHESION OF SEALANTS:

ALL CONTROL, CRACK AND EXPANSION JOINT SEALING SHOULD BE DONE PRIOR TO THE APPLICATION OF THE HYDROSHIELD WB.

 

APPLICATION:

DO NOT APPLY HYDROSHIELD WB SYSTEM WHEN THE AIR OR SURFACE TEMPERATURE OF BELOW 38 DEGREES F.

 

PRECAUTIONS:

DO NOT USE THIS PRODUCT WITHOUT READING THE MSDS SHEET AND LABEL.  DO NOT ALLOW THIS MATERIAL TO FREEZE.  DO NOT STORE MATERIAL BELOW 38 DEGREES F OR ABOVE 125 DEGREES F.  SHELF LIFE 6 TO 12 MONTHS IN UNOPENED CONTAINER.

 

PACKAGING:

5 GALLON PAILS/55 GALLON DRUMS

 

 Return to Top

 

HYDROSHEILD 20

 

TECHNICAL DATA SHEET

 

HYDROSHIELD 20

CLEAR, NON GLOSS PROTECTIVE COATING TO SEAL CONCRETE, MASONRY OR STUCCO.

 

PURPOSE:

HYDROSHIELD 20 HAS BEEN PRIMARILY DESIGNED TO SEAL CONCRETE SLABS, DECKS, WALLS, AND ABUTMENTS FROM BOTH WATER AND CHLORIDE INTRUSION WHILE PROVIDING FOR WATER VAPOR TRANSMISSION (BREATHABILITY).

 

THE HYDROSHIELD 20 SYSTEMS CONSISTS OF TWO COAT (SYNERGISTIC) APPLICATION PROCESS.  THE PRIME COAT IS AN OLIGOMERIC ALKOXY-SILANE WHICH CHEMICALLY BONDS TO THE SUBSTRATE BY REACTING WITH MOISTURE EITHER PRESENT IN THE SUBSTRATE OR IN THE ATMOSPHERE.  THE HIGHLY HYDROPHOBIC CHEMICAL MOLECULES ARE EXTREMELY SMALL (17A) RESULTING IN PENETRATION DEPTHS OF 1/4 OF AN INCH.  THIS MATERIAL IS UV RESISTANT WAND WILL NOT TURN YELLOW, AND PROVIDES A BARRIER TO DESTRUCTIVE CARBONATION.

HYDROSHIELD 20 IS 100% OLIGOMERIC ALKOXY-SILANE MATERIALS.

 

ADVANTAGES:

l    MARKEDLY REDUCES WATER AND CHLORIDE INTRUSION

l BREATHABLE PROVIDING FOR WATER VAPOR TRANSMISSION

l    CHEMICALLY RESISTANT TO ICE MELTING COMPOUNDS, FUELS, OILS AND ATMOSPHERIC          CONTAMINANTS

l INHIBITS EFFLORENCE

l INCREASES FREEZE-THAW RESISTANCE

l PREVENTS STAINING AND DISCOLORATION DUE TO ELECTROSTATIC ATTRACTION OF DUST      PARTICLES

l CAN BE APPLIED TO DAMP SURFACES

l DEEP PENETRATION INTO SUBSTRATE

l PROVIDES A BARRIER TO DESTRUCTIVE CARBONATION

 

 

SURFACE PREPARATION:

THE SUBSTRATE SHOULD BE STRUCTURALLY SOUND AND FREE OF GREASE, OIL, SEALERS, COATINGS OR OTHER SURFACE CONTAMINANTS.  HYDROSHIELD 20 MAY BE APPLIED TO DAMP SURFACES PROVIDED NO SURFACE LIQUID EXISTS.

 

APPLICATION:

HYDROSHIELD 20 CAN BE APPLIED DIRECTLY FROM THE CAN, NO THINNING.  THE PRIME COAT OF THE HYDROSHIELD 20 SHOULD BE ALLOWED TO DRY FOR AT LEAST ½ HOUR BEFORE THE TOP COAT IS APPLIED.

 

HYDROSHIELD 20                                                                            APPLICATION COVERAGE

PRIME COAT........................................................................................100 SQ. FT PER GALLON

TOP COAT.............................................................................................200 SQ. FT PER GALLON

HYDROSHIELD 20...................................................................100-125 SQ FT PER GALLON                       

THEY MAY BE EITHER SPRAYED OR ROLLER APPLIED

 

 

APPEARANCE:

THE HYDROSHIELD 20 SYSTEM WILL SLIGHTLY DARKEN THE SURFACE APPEARANCE OF THE SUBSTRATE IT IS APPLIED TO.  HYDROSHIELD 20 WILL NOT ALTER EITHER THE COLOR OR TEXTURE OF THE SURFACE.

 

ADHESION OF SEALANTS:

ALL CONTROL, CRACK AND EXPANSION JOINT SEALING SHOULD BE DONE PRIOR TO THE APPLICATION OF THE HYDROSHIELD 20.

 

APPLICATION:

DO NOT APPLY IN DIRECT SUNLIGHT WHEN TEMPERATURE IS OVER 90 DEGREES F.  DO NOT APPLY PRIME COAT WHEN AIR OR SURFACE TEMPERATURE IS BELOW 15 DEGREES F.  DO NOT APPLY TOP COAT OF THE HYDROSHIELD 20 SYSTEM WHEN AIR OR SURFACE TEMPERATURE IS BELOW 40 DEGREES F.

 

PRECAUTIONS:

DO NOT USE THIS PRODUCT WITHOUT READING THE MSDS SHEET AND LABEL.

 

PACKAGING:

5 GALLON PAILS/55 GALLON DRUMS

HYDROSHEILD 40

 

TECHNICAL DATA SHEET

 

HYDROSHIELD 40

CLEAR, NON GLOSS PROTECTIVE COATING TO SEAL CONCRETE, MASONRY OR STUCCO.

 

PURPOSE:

HYDROSHIELD 40 HAS BEEN PRIMARILY DESIGNED TO SEAL CONCRETE SLABS, DECKS, WALLS, AND ABUTMENTS FROM BOTH WATER AND CHLORIDE INTRUSION WHILE PROVIDING FOR WATER VAPOR TRANSMISSION (BREATHABILITY).

 

THE HYDROSHIELD 40 SYSTEMS CONSISTS OF TWO COAT (SYNERGISTIC) APPLICATION PROCESS.  THE PRIME COAT IS AN OLIGOMERIC ALKOXY-SILANE WHICH CHEMICALLY BONDS TO THE SUBSTRATE BY REACTING WITH MOISTURE EITHER PRESENT IN THE SUBSTRATE OR IN THE ATMOSPHERE.  THE HIGHLY HYDROPHOBIC CHEMICAL MOLECULES ARE EXTREMELY SMALL (17A) RESULTING IN PENETRATION DEPTHS OF 1/4 OF AN INCH.  THIS MATERIAL IS UV RESISTANT WAND WILL NOT TURN YELLOW, AND PROVIDES A BARRIER TO DESTRUCTIVE CARBONATION.

HYDROSHIELD 40 IS 100% OLIGOMERIC ALKOXY-SILANE MATERIALS.

 

ADVANTAGES:

l    MARKEDLY REDUCES WATER AND CHLORIDE INTRUSION

l BREATHABLE PROVIDING FOR WATER VAPOR TRANSMISSION

l CHEMICALLY RESISTANT TO ICE MELTING COMPOUNDS, FUELS, OILS AND ATMOSPHERIC               CONTAMINANTS

l INHIBITS EFFLORENCE

l INCREASES FREEZE-THAW RESISTANCE

l PREVENTS STAINING AND DISCOLORATION DUE TO ELECTROSTATIC ATTRACTION OF DUST      PARTICLES

l CAN BE APPLIED TO DAMP SURFACES

l DEEP PENETRATION INTO SUBSTRATE

l PROVIDES A BARRIER TO DESTRUCTIVE CARBONATION

 

 

SURFACE PREPARATION:

THE SUBSTRATE SHOULD BE STRUCTURALLY SOUND AND FREE OF GREASE, OIL, SEALERS, COATINGS OR OTHER SURFACE CONTAMINANTS.  HYDROSHIELD 40 MAY BE APPLIED TO DAMP SURFACES PROVIDED NO SURFACE LIQUID EXISTS.

 

APPLICATION:

HYDROSHIELD 40 CAN BE APPLIED DIRECTLY FROM THE CAN, NO THINNING.  THE PRIME COAT OF THE HYDROSHIELD 40 SHOULD BE ALLOWED TO DRY FOR AT LEAST ½ HOUR BEFORE THE TOP COAT IS APPLIED.

 

HYDROSHIELD 40                                                                            APPLICATION COVERAGE

PRIME COAT.........................................................................................100 SQ. FT PER GALLON

TOP COAT..............................................................................................200 SQ. FT PER GALLON

HYDROSHIELD 40...................................................................100-125 SQ FT PER GALLON                       

THEY MAY BE EITHER SPRAYED OR ROLLER APPLIED

 

 

APPEARANCE:

THE HYDROSHIELD 40 SYSTEM WILL SLIGHTLY DARKEN THE SURFACE APPEARANCE OF THE SUBSTRATE IT IS APPLIED TO.  HYDROSHIELD 40 WILL NOT ALTER EITHER THE COLOR OR TEXTURE OF THE SURFACE.

 

ADHESION OF SEALANTS:

ALL CONTROL, CRACK AND EXPANSION JOINT SEALING SHOULD BE DONE PRIOR TO THE APPLICATION OF THE HYDROSHIELD 40.

 

APPLICATION:

DO NOT APPLY IN DIRECT SUNLIGHT WHEN TEMPERATURE IS OVER 90 DEGREES F.  DO NOT APPLY PRIME COAT WHEN AIR OR SURFACE TEMPERATURE IS BELOW 15 DEGREES F.  DO NOT APPLY TOP COAT OF THE HYDROSHIELD 40 SYSTEM WHEN AIR OR SURFACE TEMPERATURE IS BELOW 40 DEGREES F.

 

PRECAUTIONS:

DO NOT USE THIS PRODUCT WITHOUT READING THE MSDS SHEET AND LABEL.

 

PACKAGING:

5 GALLON PAILS/55 GALLON DRUMS

Copyright 2006 ELS Products Corp | Homepage | Site Map | Web Design by NYLI